N9K-C9316D-GX Specification |
|
Ports | ? 16 x 400/100/40-Gbps QSFP-DD ports |
Physical | ? System memory: 16 GB NX-OS, 24 GB ACI
? Solid-State Disk (SSD): 128 GB ? USB: 1 port ? RS-232 serial console ports: 1 ? Management ports: 2 (1 x 10/100/1000BASE-T and 1 x 1-Gbps SFP+) ? Broadwell-DE CPU: 4 cores ? Dimensions (H x W x D): 3.38 x 17.37 x 22.27 in. (8.59 x 44.13 x 56.58 cm) |
Packet buffer | ? 80 MB centralized buffer |
Cooling | ? Fans: NXA-FAN-35CFM-PI and NXA-FAN-35CFM-PE
? 5+1 redundancy ? Port-side intake or port-side exhaust airflow direction ? Hot swappable: Yes |
Power | ? AC:
? 1100 Watt (W) AC power supplies (up to 2) ? 1+1 redundancy ? 80 Plus Platinum-rated power supplies with efficiency of 90% or greater (20 to 100% load) ? Frequency: 50 to 60 Hz (AC) ? RoHS compliance: Yes ? Hot swappable: Yes ? Port-side intake or port-side exhaust options ? Typical power: 650W (AC) ? DC: ? 1100 Watt (W) DC power supplies (up to 2) ? 1+1 redundancy ? 80 Plus Platinum-rated power supplies with efficiency of 90% or greater (20 to 100% load) ? High-voltage AC/DC ? Power: 1200W AC, 930W DC, or 1200W HVAC/HVDC ? Input voltage: 100 to 240V * AC or –40 to –72V DC (minimum and maximum), –48 to –60V DC (nominal) |
Environmental | ? Operating temperature: 32 to 104°F (0 to 40°C)
? Nonoperating (storage) temperature: -40 to 158°F ? (-40 to 70°C) ? Humidity: 5 to 85% (noncondensing) ? Altitude: 0 to 13,123 ft (0 to 4000m) |
Maximum number of IPv4 Longest Prefix Match (LPM) routes | 896,000 |
Maximum number of IPv4 host entries | 896,000 |
Maximum number of MAC address entries | 256,000 |
Maximum number of multicast routes | 32,000 |
Number of Interior Gateway Management Protocol (IGMP) snooping groups | Shipping: 8000
Maximum: 32,000 |
Maximum number of Access-Control-List (ACL) entries | Per slice of the forwarding engine:
? 5000 ingress ? 2000 egress ? Max: 20,000 ingress, 8000 egress |
Maximum number of VLANs | 3967 |
Number of Virtual Routing and Forwarding (VRF) instances | Shipping: 1000
Maximum: 16,000 |
Maximum number of ECMP paths | 64 |
Maximum number of port channels | 512 |
Maximum number of links in a port channel | 32 |
Number of active SPAN sessions | 4 |
Maximum number of VLANs in Rapid per-VLAN Spanning Tree (RPVST) instances | 3967 |
Maximum number of Hot-Standby Router Protocol (HSRP) groups | 490 |
Maximum number of Multiple Spanning Tree (MST) instances | 64 |
Flow-table size used for Cisco Tetration Analytics platform | 64,000 |
Number of Network Address Translation (NAT) entries | 1023 |
Regulatory compliance | Products should comply with CE Markings according to directives 2004/108/EC and 2006/95/EC. |
Safety | ? UL 60950-1 Second Edition
? CAN/CSA-C22.2 No. 60950-1 Second Edition ? EN 60950-1 Second Edition ? IEC 60950-1 Second Edition ? AS/NZS 60950-1 ? GB4943 |
EMC: Emissions | ? 47CFR Part 15 (CFR 47) Class A
? AS/NZS CISPR22 Class A ? CISPR22 Class A ? EN55022 Class A ? ICES003 Class A ? VCCI Class A ? EN61000-3-2 ? EN61000-3-3 ? KN22 Class A ? CNS13438 Class A Note: Cisco Nexus N9K-C9364C passes EMC Radiated Emissions standards in all configurations, with the only exception being if more than 40 pluggable optics of Cisco part number 10-3142-02 (or 10-3142-01) are used. |
EMC: Immunity | ? EN55024
? CISPR24 ? EN300386 ? KN 61000-4 series |
RoHS | The product is RoHS-6 compliant with exceptions for leaded Ball Grid-Array (BGA) balls and lead press-fit connectors. |